Last edited by Dadal
Sunday, August 9, 2020 | History

2 edition of Testing of glass volumetric apparatus. found in the catalog.

Testing of glass volumetric apparatus.

United States. National Bureau of Standards.

Testing of glass volumetric apparatus.

by United States. National Bureau of Standards.

  • 303 Want to read
  • 30 Currently reading

Published by Govt. Print. Office in Washington .
Written in English

    Subjects:
  • Volumetric apparatus.

  • Edition Notes

    SeriesCircular of the Bureau of Standards -- no. 9
    The Physical Object
    Pagination32 p.
    Number of Pages32
    ID Numbers
    Open LibraryOL22965025M

    Selected Procedures for Volumetric Calibrations ( Ed) Harris, Georgia L. Weights and Measures Division March U.S. Department of Commerce John E. Bryson, Secretary National Institute of Standards and Technology Patrick D. Gallagher, Under Secretary of Commerce for Standards and Technology and Director. Droplets of the reagent solution on the surface of the greasy glass. It is impossible to account for volume of these droplets, so you will never know what volume of the reagent was used - and as the precision of the volume measurements is the basis of the precision of the volumetric methods, dirty volumetric glass means huge errors.

    Volumetric Flasks. Strict quality assurance from The Lab Depot for Volumetric Flasks and more than , other laboratory products means that you will always have confidence in your research and development or quality control all, your laboratory testing procedures should always include using only the very best – whether volumetric flasks, chemicals, laboratory glassware or. Introduction to Medical Laboratory Technology presents the development in the medical laboratory science. It discusses the general laboratory glassware and apparatus. It addresses a more specialized procedure in mechanization, automation, and data processing.

    Soda-lime glass items will generally necessitate twice as many recalibrations as items constructed from borosilicate glass. ASTM and ISO international standards for calibration of laboratory volumetric glassware recommend that volumetric flasks are recalibrated at the following intervals (or sooner if chemical corrosion is observed. Glass volumetric pipets are also known as transfer pipets. Calibrated “to deliver” (TD), and no “blow-out” is required to accurately empty the pipet. Four sizes are available. See more product details. Options: (Select option to see volume pricing availability).


Share this book
You might also like
Creation versus chaos

Creation versus chaos

History of Clay County, South Dakota

History of Clay County, South Dakota

story of papas wise dogs

story of papas wise dogs

The Adventures of Huckleberry Finn

The Adventures of Huckleberry Finn

Second thoughts

Second thoughts

Chinese nursery rhymes.

Chinese nursery rhymes.

Divorce among the gulls

Divorce among the gulls

Military requirements for petty officer 3 & 2.

Military requirements for petty officer 3 & 2.

Poetical greetings from the Far East

Poetical greetings from the Far East

State and local government on the Net

State and local government on the Net

ASTRO-DATA 2

ASTRO-DATA 2

Contract bridge complete.

Contract bridge complete.

Monasticism, ancient and modern

Monasticism, ancient and modern

Inflation in fixed exchange rate regimes

Inflation in fixed exchange rate regimes

The future of Ally Pally

The future of Ally Pally

Politics

Politics

children of the cold

children of the cold

Testing of glass volumetric apparatus by United States. National Bureau of Standards. Download PDF EPUB FB2

Testing of glass volumetric apparatus [Hughes, John Chapman] on *FREE* shipping on qualifying offers. Testing of glass volumetric apparatus. Additional Physical Format: Online version: Hughes, John Chapman, Testing of glass volumetric apparatus.

Washington, U.S. Dept. of Commerce, National Bureau of. Additional Physical Format: Online version: Peffer, Elmer Line, Testing of glass volumetric apparatus. Washington, U.S. Govt. Print. Off., texts All Books All Texts latest This Just In Smithsonian Libraries FEDLINK (US) Avero Sound San Diego Sports Domination Podcasts HFSItsAPodcast CELTIC Test OPodden The testing of glass volumetric apparatus Item Preview remove-circle Share or Embed This Item.

TestingofGlassVoliunctricApparatus, The graduationsshouldbe of uniform width,continuous and finely but distinctlyetched, andmust beperpendicular to theaxis of the. Download PDF: Sorry, we are unable to provide the full text but you may find it at the following location(s): (external link) http. Laboratory glassware - Volumetric glassware - Methods for use and testing of capacity Verrerie de labora toire - Verrerie volum&rigue - Mhthodes d’utlJlsation et de v&ifica tion la capacith First edition - UDC Ref.

IS0 (E). Cleaning of Glassware. Labware Washing Machines. Volumetric glassware must be washed and dried before use as unclean glassware can introduce contamination errors. Soak used glassware in water and drain. Clean with a cleaning detergent. Rinse with dilute potassium dichromate solution in sulphuric acid.

In volumetric analysis, the volumes of the various solutions should be measured accurately. The apparatus required is as follows: Graduated-burette, pipette, measuring flasks, measuring cylinders, titration flasks, beakers, tile, glass-rod, funnel and wash bottle.

Class ‘A’ glass Apparatus: These are used directly for analysis purpose and are received with calibration certificate Calibration of Class `B’ Glass Apparatus: On receiving class ‘B’ Apparatus, allot ID.

as follows; Volumetric Flask, VF Transfer pipettes, TP Burettes, BT   Report issued by the Bureau of Standards over testing conducted on volumetric glass apparatus. Types of glass apparatus being tested are presented and discussed.

The results of the testing are also discussed. This report includes tables, illustrations, and by: 1. General Tests, Processes and Apparatus includes common methods for tests, useful test methods for quality recognition matography, heavy metals determination, test for glass containers for injections, infrared spectrophotometry, glass-stoppered, volumetric cylinder D.

By reference to Tablea suitable volume of distillate. NOTE General requirements and definitions of terms of piston-operated volumetric apparatus are given in ISO Conformity testing (type evaluation) of piston-operated volumetric apparatus is given in ISO Alternative test methods su ch as photometric and titrimetric methods will be the subject of a future Part 7 to ISO Standard Specification for Laboratory Glass Microvolumetric Vessels (Volumetric Flasks and Centrifuge Tubes) API MPM CH MANUAL OF PETROLEUM MEASUREMENT STANDARDS - CHAPTER STANDARD TEST METHOD FOR WATER AND SEDIMENT IN FUEL OILS BY THE CENTRIFUGE METHOD (LABORATORY PROCEDURE).

Calibration of Volumetric Glassware used in Pharmaceuticals Calibration of laboratory glass ware class A and class B, pipette / graduated pipette / burette and volumetric. buy astm e specification for laboratory glass volumetric apparatus from sai global.

Most of the volumetric apparatus available in the United States is calibrated at 20, although the temperatures generally prevailing in laboratories more nearly approach To minimize volumetric error, the temperature should be the same for the volumetric apparatus, the material being prepared, the solvents being used to prepare the volumetric solutions, the area in which they are prepared, and the final volume adjustment.

Principle: This is a full-scale room test. Test Apparatus: Burn room, no specific size, but at least × × m high; thermocouple (unspecified gauge) over the center of the chair, m above the floor. (This could make it exactly on the ceiling; it is presumed the actual procedure used involves placing it slightly below the ceiling.).

E() Standard Practice for Performance Testing of Packaged Laboratory Apparatus for United States Government Procurements. E Standard Specification for Piston or Plunger Operated Volumetric Apparatus. E()e1 Standard Specification for Sampling and Testing of Reusable Laboratory Glassware.

Errors introduced are due principally to following causes: (a) volumetric inaccuracy, (b) variation of bore, (c) delivery time, (d) incorrect marking of the meniscus, (e) after‐working of the glass. Elimination of errors due to these causes is discussed.

An apparatus for the calibration of volumetric apparatus. A volumetric flask (measuring flask or graduated flask) is a piece of laboratory apparatus, a type of laboratory flask, calibrated to contain a precise volume at a certain tric flasks are used for precise dilutions and preparation of standard flasks are usually pear-shaped, with a flat bottom, and made of glass or plastic.All volumetric glassware for quantitative work requires calibration.

6. Range All volumetric glassware used for accurate delivery or to contain specific volumes needs to be calibrated. 7. Apparatus and Equipment Analytical balance accurate to mg (g) Analytical balance accurate to g.

(For volumes of mL or less, the balance.Standardization of devices and apparatus for laboratory purposes, with respect to principles and to materials of construction, performance, dimensions and testing, as well as the terms and definitions used in connection therewith. The relative emphasis to be placed on standards of performance and on .